The RapiTrim workstation
enables the realization of full production for embedded passive trim and
test. Through the use of proprietary fixtureless technology, probe
cards and their inherent limitations are eliminated. Restrictions on
design layout have been lifted, and operational delays waiting for probe
cards have been removed.
 |
|
| RapiTrim |
| Integrated laser
trimming tool for high volume production |
| Unique, proprietary
fixtureless technology for rapid, accurate trim and test operations |
| Optional full Kelvin
probe tips |
| Independent of circuit
size or shape |
| Independent of component
size, shape or orientation |
| Compatible with both thin
film and thick film materials |
| Fast job changeover for
prototype work |
| Slip sheet and panel
flipper options |
| Windows® operator
interface |
| |
RapiTrim data
sheet
RapiTrimä
is a breakthrough new concept in production workstations for embedded
passive and hybrid trim and test. Users experience all the benefits of a
fixtureless system without the sacrifice of slow trimming speed. Circuit
designers are no longer limited by the practical size limit on probe card
designs; circuits can be as large as the panel itself. Each of the four
probes as well as the galvanometer-located laser beam have access to the
whole 50x50mm field, ensuring that any component location, size,
orientation and component density can be accommodated. Probe fields are
tiled together using the high accuracy XY stages. The small field size
allows the use of a smaller, lighter probe positioning mechanism, leading
to rapid, accurate probe tip movement.
In addition, the system
can function as a stand-alone tester, with the trimming function turned
off.
Specifications*
|
System Hardware |
|
· Fast, high accuracy
probe movement over 50x50mm field |
|
· Standard or full
Kelvin probe tips |
|
· Isolated components use two probe tips; three probes available
for trimming networked resistors |
|
· Automated probe tip
calibration
|
|
· Automated vision
system for precision alignment, and scaling, offset, trapezoidal
and rotation compensation |
|
· Automated laser power
calibration with integrated power meter |
|
· Configured with high
performance galvanometers for high speed trimming |
|
· High performance motion and laser controller |
|
· Galvanometer scanning
field: 50x50 mm |
|
· Maximum panel size
533mm x 635mm (21" x 25") |
|
· Vacuum platen for
panel hold-down· |
|
· Beam and probe placement accuracy: 15µm (3
sigma) over panel process area |
|
· Ultra-stable steel weldment frame with resonance dampening |
|
· Compliant with CE and North American regulations |
|
· |
|
· Optional automatic
panel loader/unloader |
|
|
|
Utilities
|
|
· Electrical: 208 VAC, three phase, 5-wire "WYE",
15A, 60Hz; or 400 VAC, three phase, 5-wire "WYE", 10A,
50Hz. |
|
· Exhaust: ablation debris removal through
3" (76mm) diameter duct, 100 SCFM typical |
|
· Dimensions (HxWxD):
93"x64"x86"
2356mm x 1626mm x
2192mm without optional load/unload bays |
|
· Weight: 2813 kg (6233
lbs) net |
|
|
| |
|
|
|
System Control |
|
· Windows XP® based user interface
|
|
· User friendly
operator screens |
|
· Compatible with all industry standard file formats |
|
· Rapid file
conversion and path optimization utility. |
|
· Trim parameters are
pre-defined in a tool Library, with custom tool generation
available |
|
· System monitoring for
process integrity |
|
· Full system
diagnostics |
|
·Saving of multiple job
parameter files |
|
·Password protection
for access to configuration, set-up, and operating screens |
|
·Emergency stop and
safety interlock circuits |
|
|
|
Optional network
interface |
|
|
|
Process Parameters |
|
· Single-plunge,
double-plunge and L-cuts available |
|
· Up to 50 test points/sec. |
|
· Resistance measured in real time using high speed A/D converter |
|
· All measurement data logged as part of normal operation |
|
· Minimum test pad size: 200µm for
single tip, 400µm for double tip |
|
· Resistor range: 0.1 Ohm to 100 MOhm |
|
· Typical trimmed resistor distribution <1% (3σ) |
|
· Wide control of laser pulse energy, repetition rate and step
size. |
|
|
|
· Consult PPI for processing trials for your circuits. |
|
|
| * specifications are subject to
revision and change |
|
▲[top] |
|
|
|